beta

You're viewing our new website - find out more

Publication - Report

Energy Efficiency Standard for Social Housing: peer review

Published: 22 Oct 2013
Part of:
Environment and climate change
ISBN:
9781782569961

Peer review scrutinising the example dwellings in the Energy Efficiency Standard for Social Housing consultation document.

246 page PDF

3.8MB

246 page PDF

3.8MB

Contents
Energy Efficiency Standard for Social Housing: peer review
Appendix A - Housing Stock Summary

246 page PDF

3.8MB

Appendix A - Housing Stock Summary

Building form Construction Period Current Scottish Stock [1] Example Dwelling Representation Additional Hard-to-treat representation
000s (% of stock) No. Reference (Group) No. References
Tenements Pre 1919 166 (7.1 %) 3 A1: Solid wall, ground floor, mid terrace

A2: Solid wall, mid-floor, mid terrace

A3: Solid wall, top floor, mid terrace
2 HTT- HTT-1: Solid wall, gable end, ground floor

HTT-2: Solid wall, gable end, top floor, partial flat roof
1919 - 1944 45 (1.9 %) 1 B4: 1919-1929, cavity wall, mid-floor
1945 - 1964 107 (4.5 %) 1 D9: 1950-1964, cavity wall, mid-floor 2 HTT-7: No Fines Concrete, ground floor, gable end

HTT-8: No Fines Concrete, top floor, gable end
1965 - 1982 94 (4.0 %) 1 E12: 1965-1975, cavity wall, mid-floor
Post 1982 124 (5.3 %) 3 F15: 1984-1991 insulated wall, mid-floor G18: 1992-1998 insulated wall, mid-floor H21: 1999-2007 insulated wall, mid-floor
Other Flats Pre 1919 56 (2.4 %)
1919 - 1944 103 (4.4 %) 2 C7: Lower 4 in a block C8: Upper 4 in a block
1945 - 1964 79 (3.4 %)
1965 - 1982 46 (2.0 %)
Post 1982 43 (1.8 %)
Terraced Houses Pre 1919 67 (2.8 %)
1919 - 1944 37 (1.6 %) 1 B5: 1919-1929, cavity wall, mid-terrace
1945 - 1964 175 (7.4 %) 1 D10: 1950-1964, cavity wall, mid-terrace
1965 - 1982 163 (6.9 %) 1 E13: 1965-1975, cavity wall, mid-terrace
Post 1982 54 (2.3 %) 3 F16: 1984-1991. insulated wall G19: 1992-1998, insulated wall H22: 1999-2007, insulated wall
Semi-detached houses Pre 1919 62 (2.6 %)
1919 - 1944 73 (3.1 %) 1 B6: 1919-1929, cavity wall
1945 - 1964 145 (6.2 %) 1 D11: 1950-1964, cavity wall 1 HTT-10: 1950's, Timber frame, semi-detached
1965 - 1982 132 (5.6 %) 1 E14: 1965-1975, cavity wall
Post 1982 82 (3.5 %) 3 F17: 1984-1991, insulated wall G20: 1992-1998, insulated wall H23: 1999-2007 insulated wall
Detached houses Pre 1919 105 (4.5 %)
1919 - 1944 39 (1.7 %)
1945 - 1964 48 (2.0 %)
1965 - 1982 103 (4.4 %)
Post 1982 208 (8.8 %)

HTT-3: 1950-64 system built concrete multi-storey flat ground floor, gable end
HTT-4: 1950-64system built concrete multi-storey flat mid-floor, gable end
HTT-5: 1950-64 external deck access, ground floor, gable end
HTT-6: 1950-64 external deck access, mid-floor gable end
HTT-9: Swedish timber house, semi-detached
HTT-11: System built concrete house, semi-detached
HTT-12: BISF steel frame house, semi-detached

Footnotes

1. 'Scottish House Condition Survey - Key Findings 2010', The Scottish Government, November 2011


Contact

Email: Agnes Meany